Mold Base Standard Plate Templates
-
Overview
- Standard Plate templates refer to Mold Bases without a H-plate in it, as illustrated below
- Currently the library contains 4 different Standard Plate Mold Bases
- SMC Tool with no Cover Build up

- Tool has no cover rails or plates, or any standard elements for a cover buildup
- Contains Ej Clamp Plate, Ej Back Plate, Ej Pin Plate, Ej Rails, Ejector Block, and Cover Block
- Cover/Ejector Block have a default size of 70″ x 35″ x 25″ (all these dimensions are editable)
- SMC Tool with Cover Build up

- Contains Ej Clamp Plate, Ej Back Plate, Ej Pin Plate, Ej Rails, Ejector Block, Cover Block, Cover Rails, and a Cover Clamp Plate
- Cover/Ejector Block have a default size of 70″ x 35″ x 25″ (all these dimensions are editable)
- Small SMC Tool with Cover Build up

- Contains Ej Clamp Plate, Ej Back Plate, Ej Pin Plate, Ej Rails, Ejector Block, Cover Block, Cover Rails, and a Cover Clamp Plate
- Cover/Ejector Block have a default size of 35″ x 20″ x 12″ (all these dimensions are editable)
- SMC Tool with Insulator Board

- Tool has no cover rails
- Contains Ej Insulator Board, Ej Clamp Plate, Ej Back Plate, Ej Pin Plate, Ej Rails, Ejector Block, Cover Block, Cover Insulator board, and a Cover Clamp Plate
- Cover/Ejector Block have a default size of 70″ x 40″ x 25″ (all these dimensions are editable)
- SMC Tool with no Cover Build up
- Standard Plate templates refer to Mold Bases without a H-plate in it, as illustrated below
-
Template Specific Information
- Editing Tool Parameters
- Once the Mold Base template has been selected, click on the folder shown below to edit the Tool Parameters
- Here we can edit the tool length, width, gap between plates and rails, injection opening value
- Also, in the tool information section, we can see the overall tool height and the ejector stroke
- These values update automatically when adjusting plate, block, and rail sizes
- Also, in the tool information section, we can see the overall tool height and the ejector stroke
- The gap between rails and plates parameter refers to the amount of space between a rail and a plate, as shown below
- The injection opening value overlaps the cover block with the ejector block
- If you put in a value of -10.0″, the cover block and all the pertaining plates and rails for the cover build up will be shifted down -10.0″ as illustrated below
- If you put in a value of -10.0″, the cover block and all the pertaining plates and rails for the cover build up will be shifted down -10.0″ as illustrated below
- Once the Mold Base template has been selected, click on the folder shown below to edit the Tool Parameters
- Editing Tool Parameters
-
Additional Information
- Mold Base – How to Guide
- Contains more information regarding standard plates templates
- Mold Base H-Plate Templates
- Contains more information regarding H-plate plates templates
- Mold Base Standard Elements
- Contains more information regarding Standard Elements
- Mold Base – How to Guide